
14 |
Power supply
POWER SUPPLY
The switching unit must be connected in accordance with the following description:
Clamper name Function
L
Supply phase of the equipment and the
connected devices.
N Working zero
FAN Fan connection.
COMP Connection of compressor´s contactor.
HEAT Connection of electro valve
control.
FROST NTC sensor of ice coating.
OVHEAT NTC sensor of compressor´s overheating.
COM Common wire (conductor)
sensors.
The switching unit is delivered with an installed resistor 1K between FROST and COM
clampers. This way it is prepared for operation without NTC heat sensors. In case of
sensors´ connection, it is necessary to disconnect the resistor.
Never disconnect the antenna from the receiver if the equipment is under pressure.
Important warning:
This may damage the receiver. Make sure that you always disconnect the energy supply first
when intending to disconnect the antenna.
Comentários a estes Manuais